- Product No.SEB278Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range31.2-2,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 12.1pg/mL.
Specificity
This assay has high sensitivity and excellent specificity for detection of Fc Fragment Of IgG Low Affinity IIIa Receptor (FcgR3A).
No significant cross-reactivity or interference between Fc Fragment Of IgG Low Affinity IIIa Receptor (FcgR3A) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Fc Fragment Of IgG Low Affinity IIIa Receptor (FcgR3A) and the recovery rates were calculated by comparing the measured value to the expected amount of Fc Fragment Of IgG Low Affinity IIIa Receptor (FcgR3A) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 97-105 | 101 |
| EDTA plasma(n=5) | 78-92 | 86 |
| heparin plasma(n=5) | 78-94 | 82 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fc Fragment Of IgG Low Affinity IIIa Receptor (FcgR3A) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fc Fragment Of IgG Low Affinity IIIa Receptor (FcgR3A) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fc Fragment Of IgG Low Affinity IIIa Receptor (FcgR3A) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 93-101% | 89-97% | 79-89% | 94-104% |
| EDTA plasma(n=5) | 78-101% | 96-103% | 94-104% | 81-92% |
| heparin plasma(n=5) | 86-103% | 80-96% | 98-105% | 84-95% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
QIAamp DNA Blood Mini Kit (250) - 51106 - Qiagen
911015119999 D2012 Plus High Speed Personal Micro-Centrifuge Scilogex
RE301C-O - Rotary evaporator, Glass "C", Oil BathRE301C-O - Yamato
D4075- Quick-DNA Midiprep Plus Kit- Zymo Research
840003 Digital Anemometer Thermometer Sper Scientific
A-104271, 3-Part Life-Size Painted Didactic Human Skull Axis Scientific
VV0020-BOT Graduated, PC collection bottle (included) Accuris
D4074- Quick-DNA Microprep Plus Kit- Zymo Research
RE601B-W - Rotary EvaporatorRE601B-W - Yamato
A-105176 Disarticulated Half Child Skeleton Axis Scientific
BSW13 Block For Digital Dry Bath - 20 x 12mm or 20 x 13mm Test Tubes Benchmark Scientific 