Standard type of natural convec-tion constant temperature drying ovens, with extensive features and simple operation.
Performance and functions
- Economical and cost saving
- Easy to use and maintain
- Excellent temperature accuracy
- Digital PID controller for easy constant operation with options of Fixed setting
- Quick Auto Stop, Auto Start, Auto Stop operation
- Increased safety and self-diagnostic function
- Calibration off-set function
Safety features
- Temp sensor error, Temp input circuit error, Auto overheat prevention, Measured temp error, Circuit breaker with over current protection
| Model | DX302C DX312C |
DX402C DX412C |
DX602C DX612C |
| Circulation Method | Natural gravity convection | ||
| Operating temp. range | Room temp. +5°C to 300°C | Room temp. +5°C to 280°C | |
| Temperature Control Accuracy | ±1°C (at 300°C) | ||
| Temperature Distribution Accuracy | ±10°C (at 300°C) | ±10°C (at 280°C) | |
| Maximum Temperature Reaching Time | ~45 min (Room temp. to 300°C) | ~60 min (Room temp. to 300°C) | ~80 min (Room temp. to 280°C) |
| Interior Material | Stainless steel | ||
| Exterior Material | Electro-galvanized steel sheet with melamine resin baking finish | ||
| Heat Insulating Material | Glass wool | ||
| Heater | Iron-chrome wire heater 0.9 kW | Iron-chrome wire heater 1.36 kW | Iron-chrome wire heater 1.36 kW |
| Exhaust Port | 33 mm I.D. x 2 pcs. (on top) | ||
| Temp. Controller | PID control by microprocessor | ||
| Temp. Setting Method | Digital setting by ▲▼ key | ||
| Temp. Display Method | Measurement temp. : Digital display by green LED / Setting temp. : Digital display by red LED | ||
| Timer | 1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50 min. | ||
| Operation Function | Fixed temperature, Quick auto stop, Auto stop, Auto start | ||
| Additional Function | Calibration off-set, Power failure compensation function, Key lock function | ||
| Heater Circuit Control | SSR control | ||
| Sensor | K-thermocouple | ||
| Safety Device | Self diagnostic functions (Temp. Sensor abnormal, Abnormal memory, Input temp. abnormal, Measured temp. abnormal, Automatic overheat prevention), Key lock function, Hydraulic independent overheat prevention device, Electric leakage breaker with over current protection | ||
| Internal Dimensions W×D×H | 300x310x300mm | 450x410x400mm | 600x510x500mm |
| External Dimensions W×D×H | 400x440x630mm | 550x540x730mm | 700x640x830mm |
| Internal Capacity | 28L | 74L | 153L |
| Shelf Plate With Standard Load | 15kg/piece | 15kg/piece | 15kg/piece |
| Shelf Rest Step Number / Pitch | 6 steps / 35mm | 9 steps / 35mm | 12 steps / 35mm |
| Power Source 50/60Hz | AC115V 9.5A (with plug) AC220V 4.3A (no plug, round terminal) |
AC115V 14A (with plug) AC220V 6.4A (no plug, round terminal) |
AC115V 14A (with plug) AC220V 6.4A (no plug, round terminal) |
| Weight | ~23kg | ~38kg | ~56kg |
| External Dimensions W×D×H | 400x440x630mm | 550x540x730mm | 700x640x830mm |
H5100-384- Block, 384 well plate, for MultiTherm Touch- Benchmark
HB-163 Chamber Warmer - E-Z Systems
SMO28G-2- OVEN FORCED AIR 27.5 CF 230V CERAKOTE - SHELLAB
718-8804- SAM4 Auscultation Manikin -Cardionics
19117-Smedley Hand Dynamometer- Stoelting
701221110- FreeZone 12 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
HCB 1002 -Highland® Portable Precision Balances- Adam Equipment
PAA142HU01-Anti-ST14 Mouse Monoclonal Antibody [clone: C4]-Cloud-Clone
H5100-CMB- Combination block, 15x0.5ml and 20x1.5ml, for MultiTherm Touch- Benchmark
PMB 202 - PMB Moisture Analyzer-Adam Equipment
H5100-500- Block, 4x50ml, for MultiTherm Touch- Benchmark
RE301A-OV - Rotary evaporator, Glass "A", Oil Bath, VR300- Yamato
YS3010, Handheld Spectrophotometer with 8mm Single Aperture 3nh
H5100-150- Block, 8x15ml, for MultiTherm Touch- Benchmark
19-042E- Bead Ruptor Elite - Omni International
PT 112M Plattforms Adam Equipment
PT 112 Plattforms Adam Equipment
HCB 153 -Highland® Portable Precision Balances- Adam Equipment
WA731 - Water Purifier (Ion-exchange + Distillation, Large Capacity)WA731- Yamat 