Product Details
The QIAquick Gel Extraction Kit provides spin columns, buffers, and collection tubes for silica-membrane-based purification of DNA fragments from gels (up to 400 mg slices) or enzymatic reactions. DNA ranging from 70 bp to 10 kb is purified using a simple and fast bind-wash-elute procedure and an elution volume of 30–50 μl. An integrated pH indicator allows easy determination of the optimal pH for DNA binding to the spin column. The procedure can be fully automated on the QIAcube Connect.
For optimal results it is recommended to use this product together with QIAvac 24 Plus.
Performance
The QIAquick Gel Extraction Kit enables removal of nucleotides, enzymes, salts, agarose, ethidium bromide, and other impurities from samples, ensuring up to 80% recovery of DNA (see figure ” High recoveries from gels”). Using a microcentrifuge or vacuum manifold, DNA ranging from 70 bp to 10 kb is purified from 1–24 samples. Purified DNA can be used, for example, in sequencing (see figure ” Reliable sequencing after gel extraction”). DNA fragments smaller than 70 bp or larger than 10 kb should be extracted with the QIAEX II Gel Extraction System.
Principle
QIAquick Kits contain a silica membrane assembly for binding of DNA in high-salt buffer and elution with low-salt buffer or water. The purification procedure removes primers, nucleotides, enzymes, mineral oil, salts, agarose, ethidium bromide, and other impurities from DNA samples (see figure ” High recoveries from gels”). Silica-membrane technology eliminates the problems and inconvenience associated with loose resins and slurries. Specialized binding buffers are optimized for specific applications and promote selective adsorption of DNA molecules within particular size ranges.
Gel loading dye
To enable faster and more convenient sample processing and analysis, gel loading dye is provided. GelPilot Loading Dye contains three tracking dyes (xylene cyanol, bromophenol blue, and orange G) to facilitate the optimization of agarose gel run time and prevent smaller DNA fragments migrating too far (see figure “GelPilot Loading Dye”).
Procedure
The QIAquick system uses a simple bind-wash-elute procedure (see flowchart ” QIAquick and MinElute procedure”). Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the QIAquick spin column (see figure ” pH Indicator Dye”). Nucleic acids adsorb to the silica membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in all subsequent applications.
Handling
QIAquick spin columns are designed to provide two convenient handling options. The spin columns fit into a conventional table-top microcentrifuge or onto any vacuum manifold with luer connectors, such as the QIAvac 24 Plus with QIAvac Luer Adapters. The QIAquick Gel Extraction Kit, in addition to other QIAGEN spin-column-based kits, can be fully automated on the QIAcube, enabling increased productivity and standardization of results (see figures “Spin column handling options A, B, C, D, and E”).
Applications
DNA fragments purified with the QIAquick system are ready for direct use in all applications, including sequencing, ligation and transformation, restriction digestion, labeling, microinjection, PCR, and in vitro transcription.
| Features | Specifications |
| Binding capacity | 10 µg |
| Format | Tube |
| Fragment size | 70 bp – 10 kb |
| Recovery: oligonucleotides dsDNA | Recovery: dsDNA fragments |
| Processing | Manual |
| Removal <10mers 17–40mers dye terminator proteins | Removal <10mers |
| Elution volume | 30–50 µl |
| Technology | Silica technology |
| Sample type: applications | DNA: PCR reactions |
3970301- 3' Purifier Vertical Clean Bench with UV Light and Protection Panel- Labconco
D4074- Quick-DNA Microprep Plus Kit- Zymo Research
LAB 254e -Luna Analytical Balances- Adam Equipment
F81056-PIPETMAN M P8X300M BT Connected-Gilson
A00000001, Derivation element PW 10 Velp
19781-QIAfilter Mega-Giga Cartridges (5)- Qiagen
AZI280-Azure 280-Azure BioSystems
DC4020- DRYCHILL™ 40 X 1.5/2.0ML- Benchmark
701811010-FreeZone 18 Liter -50C Console Freeze Dryer- Labconco
711221110-FreeZone 12 Liter -84C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
700611030- FreeZone 6 Liter -50C Console Freeze Dryer- Labconco
F110128-10ML Serological Pipette 200 Individually wrapped-Gilson
H5100-02- Block, 96 well PCR plate, 96x0.2ml tubes, for MultiTherm Touch- Benchmark
701822130-FreeZone 18 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
3970305- 3' Purifier Filtered PCR Enclosure with UV Light, Protection Panel and Airflow Monitor- Labconco
FA10004P-PIPETMAN L P100L, 10-100 µL, Plastic Ejector-Gilson
F110124-2ML Serological Pipette 1000 Individually wrapped-Gilson
06-209-02 - 1.5 To 2 Ml Omni Prep Tube Holder- Omni International
710401000-FreeZone 4.5 Liter -84C Benchtop Freeze Dryer- Labconco
F110131-50ML Serological Pipette 100 Individually wrapped-Gilson
A-105170 Miniature Painted Human Skeleton Axis Scientific
06-207 - Cooling Ice Tray - For 2 Ml - 5 Ml Tubes- Omni International
81-12531-00, Omega Fluor™ Plus Gel Documentation System, 365 nm Gel Company
F110130-25ML Serological Pipette 200 Individually wrapped-Gilson
1950, T8DCS Double Beam UV-Vis Persee
LTB 4602i -Luna Precision Balances- Adam Equipment
NS800, Spectrophotometer 3nh
BCLO3003 Autoclavable Plastic Stick Grille - 90mm Box Alliance Bio Expertise
4301 Polypropylene 1.5ml Graduated Flat Top Microcentrifuge Tube, Red Bio Plas
ETB 6202i -Equinox Precision Balances- Adam Equipment
88870113, Digital and Touchscreen Dry Bath Accessories Thermo Scientific-Mixed Block, 1.5mL and 2.0mL
711211010-FreeZone 12 Liter -84C Console Freeze Dryer- Labconco
RE601B-O - Rotary EvaporatorRE601B-O - Yamato
3970402- 4' Purifier Filtered PCR Enclosure with UV Light and Protection Panel- Labconco
AZI600-Azure 600-Azure BioSystems
0052 Snap On Tube Rack Cover, 96-Well, Polypropylene, Clear Natural Bio Plas
D1000 - Homogenizer, Includes 5mm And 7mm Generators (Ideal For Microtubes) - Benchmark Scientific
701212030- FreeZone 12 Liter -50C Console Freeze Dryer- Labconco
3970300- 3' Purifier Vertical Clean Bench- Labconco
4302 Polypropylene 1.5ml Graduated Flat Top Microcentrifuge Tube, Yellow Bio Plas 


