Product Details
The QIAquick Gel Extraction Kit provides spin columns, buffers, and collection tubes for silica-membrane-based purification of DNA fragments from gels (up to 400 mg slices) or enzymatic reactions. DNA ranging from 70 bp to 10 kb is purified using a simple and fast bind-wash-elute procedure and an elution volume of 30–50 μl. An integrated pH indicator allows easy determination of the optimal pH for DNA binding to the spin column. The procedure can be fully automated on the QIAcube Connect.
For optimal results it is recommended to use this product together with QIAvac 24 Plus.
Performance
The QIAquick Gel Extraction Kit enables removal of nucleotides, enzymes, salts, agarose, ethidium bromide, and other impurities from samples, ensuring up to 80% recovery of DNA (see figure ” High recoveries from gels”). Using a microcentrifuge or vacuum manifold, DNA ranging from 70 bp to 10 kb is purified from 1–24 samples. Purified DNA can be used, for example, in sequencing (see figure ” Reliable sequencing after gel extraction”). DNA fragments smaller than 70 bp or larger than 10 kb should be extracted with the QIAEX II Gel Extraction System.
Principle
QIAquick Kits contain a silica membrane assembly for binding of DNA in high-salt buffer and elution with low-salt buffer or water. The purification procedure removes primers, nucleotides, enzymes, mineral oil, salts, agarose, ethidium bromide, and other impurities from DNA samples (see figure ” High recoveries from gels”). Silica-membrane technology eliminates the problems and inconvenience associated with loose resins and slurries. Specialized binding buffers are optimized for specific applications and promote selective adsorption of DNA molecules within particular size ranges.
Gel loading dye
To enable faster and more convenient sample processing and analysis, gel loading dye is provided. GelPilot Loading Dye contains three tracking dyes (xylene cyanol, bromophenol blue, and orange G) to facilitate the optimization of agarose gel run time and prevent smaller DNA fragments migrating too far (see figure “GelPilot Loading Dye”).
Procedure
The QIAquick system uses a simple bind-wash-elute procedure (see flowchart ” QIAquick and MinElute procedure”). Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the QIAquick spin column (see figure ” pH Indicator Dye”). Nucleic acids adsorb to the silica membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in all subsequent applications.
Handling
QIAquick spin columns are designed to provide two convenient handling options. The spin columns fit into a conventional table-top microcentrifuge or onto any vacuum manifold with luer connectors, such as the QIAvac 24 Plus with QIAvac Luer Adapters. The QIAquick Gel Extraction Kit, in addition to other QIAGEN spin-column-based kits, can be fully automated on the QIAcube, enabling increased productivity and standardization of results (see figures “Spin column handling options A, B, C, D, and E”).
Applications
DNA fragments purified with the QIAquick system are ready for direct use in all applications, including sequencing, ligation and transformation, restriction digestion, labeling, microinjection, PCR, and in vitro transcription.
| Features | Specifications |
| Binding capacity | 10 µg |
| Format | Tube |
| Fragment size | 70 bp – 10 kb |
| Recovery: oligonucleotides dsDNA | Recovery: dsDNA fragments |
| Processing | Manual |
| Removal <10mers 17–40mers dye terminator proteins | Removal <10mers |
| Elution volume | 30–50 µl |
| Technology | Silica technology |
| Sample type: applications | DNA: PCR reactions |
49000163 Occasional Service Delivery / Airwel Alliance Bio Expertise
4304 Polypropylene 1.5ml Graduated Flat Top Microcentrifuge Tube, Green Bio Plas
710612230-FreeZone 6 Liter -84C Console Freeze Dryer- Labconco
BSH100-02 Block, 40 x 0.2ml (or 5 x PCR strips) Benchmark Scientific
ETB 6202e -Equinox Precision Balances- Adam Equipment
3970420- 4' Purifier Vertical Clean Bench- Labconco
9140300 Binocular tilting observation head 0° - 25° (excluding eyepieces) Labomed
F81057-PIPETMAN M P12X300M BT Connected-Gilson
06-209-05 - 5 Ml Omni Prep Tube Holder- Omni International
F110125-5ML Serological Pipette BulkSt 20 bags of 25-Gilson
FD10002-MICROMAN E M25E, 3-25 µL-Gilson
3970300- 3' Purifier Vertical Clean Bench- Labconco
701222130- FreeZone 12 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
3970202- 2' Purifier Filtered PCR Enclosure with UV Light and Protection Panel- Labconco
ETB 3202e -Equinox Precision Balances- Adam Equipment
710612130-FreeZone 6 Liter -84C Console Freeze Dryer- Labconco
BGWR3006 Baggywel - Fraser Demi - 3 X 3l Alliance Bio Exterpise
F110128-10ML Serological Pipette 200 Individually wrapped-Gilson
F144801-PIPETMAN Classic P2-Gilson
F110131-50ML Serological Pipette 100 Individually wrapped-Gilson
0714-00 Multi-Torso - Female Only Denoyer-Geppert
06-210 - Cooling Ice Tray - For 15 Ml - 50 Ml Tubes- Omni International
S61-725 Premier Skeleton With Soft Organ Set- Denoyer Geppert
3970302- 3' Purifier Filtered PCR Enclosure with UV Light and Protection Panel- Labconco
81-12120-00, Omega Lum™ W Imaging System Gel Company
45010-Marmoset Brain in Stereotaxic Coordinates- Stoelting
T3031 - Mix & Go! XJa (DE3) Autolysis Competent Cells, 1 ml 500x L-Arabinose - 10 x 100 µl- Zymo Research
F110129-25ML Serological Pipette BulkSt 10 bags of 20-Gilson
FA10023-PIPETMAN L Fixed F50L, 50 µL-Gilson
FA10001P-PIPETMAN L P2L, 0.2-2 µL, Plastic Ejector-Gilson
BSWHEM Block, 48 x hematocrit tubes, 1.9mm (not compatible with cover) Benchmark Scientific
F110130-25ML Serological Pipette 200 Individually wrapped-Gilson
F167550-PIPETMAN L Microvolume Starter Kit, P2L, P10L, P100L-Gilson
A-104270, 3-Part Life-Size Numbered Human Skull Axis Scientific
R1056- Quick-RNA Midiprep Kit 25 preps- Zymo Research 



