Product Details
The QIAquick Gel Extraction Kit provides spin columns, buffers, and collection tubes for silica-membrane-based purification of DNA fragments from gels (up to 400 mg slices) or enzymatic reactions. DNA ranging from 70 bp to 10 kb is purified using a simple and fast bind-wash-elute procedure and an elution volume of 30–50 μl. An integrated pH indicator allows easy determination of the optimal pH for DNA binding to the spin column. The procedure can be fully automated on the QIAcube Connect.
For optimal results it is recommended to use this product together with QIAvac 24 Plus.
Performance
The QIAquick Gel Extraction Kit enables removal of nucleotides, enzymes, salts, agarose, ethidium bromide, and other impurities from samples, ensuring up to 80% recovery of DNA (see figure ” High recoveries from gels”). Using a microcentrifuge or vacuum manifold, DNA ranging from 70 bp to 10 kb is purified from 1–24 samples. Purified DNA can be used, for example, in sequencing (see figure ” Reliable sequencing after gel extraction”). DNA fragments smaller than 70 bp or larger than 10 kb should be extracted with the QIAEX II Gel Extraction System.
Principle
QIAquick Kits contain a silica membrane assembly for binding of DNA in high-salt buffer and elution with low-salt buffer or water. The purification procedure removes primers, nucleotides, enzymes, mineral oil, salts, agarose, ethidium bromide, and other impurities from DNA samples (see figure ” High recoveries from gels”). Silica-membrane technology eliminates the problems and inconvenience associated with loose resins and slurries. Specialized binding buffers are optimized for specific applications and promote selective adsorption of DNA molecules within particular size ranges.
Gel loading dye
To enable faster and more convenient sample processing and analysis, gel loading dye is provided. GelPilot Loading Dye contains three tracking dyes (xylene cyanol, bromophenol blue, and orange G) to facilitate the optimization of agarose gel run time and prevent smaller DNA fragments migrating too far (see figure “GelPilot Loading Dye”).
Procedure
The QIAquick system uses a simple bind-wash-elute procedure (see flowchart ” QIAquick and MinElute procedure”). Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the QIAquick spin column (see figure ” pH Indicator Dye”). Nucleic acids adsorb to the silica membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in all subsequent applications.
Handling
QIAquick spin columns are designed to provide two convenient handling options. The spin columns fit into a conventional table-top microcentrifuge or onto any vacuum manifold with luer connectors, such as the QIAvac 24 Plus with QIAvac Luer Adapters. The QIAquick Gel Extraction Kit, in addition to other QIAGEN spin-column-based kits, can be fully automated on the QIAcube, enabling increased productivity and standardization of results (see figures “Spin column handling options A, B, C, D, and E”).
Applications
DNA fragments purified with the QIAquick system are ready for direct use in all applications, including sequencing, ligation and transformation, restriction digestion, labeling, microinjection, PCR, and in vitro transcription.
| Features | Specifications |
| Binding capacity | 10 µg |
| Format | Tube |
| Fragment size | 70 bp – 10 kb |
| Recovery: oligonucleotides dsDNA | Recovery: dsDNA fragments |
| Processing | Manual |
| Removal <10mers 17–40mers dye terminator proteins | Removal <10mers |
| Elution volume | 30–50 µl |
| Technology | Silica technology |
| Sample type: applications | DNA: PCR reactions |
PAC060HU01-Anti-PDGFRa Rabbit Polyclonal Antibody- Cloude Clone
701222130- FreeZone 12 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
632543-Antibodies to detect orange fluorescent proteins: mOrange2- Takara
710611010-FreeZone 6 Liter -84C Console Freeze Dryer- Labconco
710201010-FreeZone 2.5 Liter -84C Benchtop Freeze Dryer- Labconco
LAB 84e -Luna Analytical Balances- Adam Equipment
3120010-802 Micrometer reticule, scale 10mm divided in 100 parts, X-axis horizontal scale with locking circlip Labomed
MAA541MU21-Anti-BNP Mouse Monoclonal Antibody [clone: C10]-Cloud-Clone
CTL-REFM-PRSG -Refractometer- LW Scientific
BCLO3011 Bar Code Cards Place X 10 Alliance Bio Expertise
0716-00 Multi-Torso With Male/Female/Gender Neutral Inserts- Denoyer Geppert
701212110- FreeZone 12 Liter -50C Console Freeze Dryer- Labconco
A-105177 Painted And Numbered 3-Part Life-Size Human Skull Axis Scientific
3970422- 4' Purifier Filtered PCR Enclosure with UV Light and Protection Panel- Labconco
711212210-FreeZone 12 Liter -84C Console Freeze Dryer- Labconco
EPB 363e -Equinox Precision Balances- Adam Equipment
FD10003-MICROMAN E M50E, 20-50 µL-Gilson
F110131-50ML Serological Pipette 100 Individually wrapped-Gilson
4304 Polypropylene 1.5ml Graduated Flat Top Microcentrifuge Tube, Green Bio Plas
SE915 Large Format PAGE Multiple Gel Caster for Use with SE9102 Cassettes Hoefer
A-104284, Premium Life-Size Muscled Arm in 7 Parts Axis Scientific
OR-C-250 - 250 ml Cup Tip For Ultrasonic Homogenizer- Omni International
74004-RNeasy Micro Kit (50)- Qiagen
88870111, Digital and Touchscreen Dry Bath Accessories Thermo Scientific-1 x 96-well Elisa Block
3970402- 4' Purifier Filtered PCR Enclosure with UV Light and Protection Panel- Labconco
19781-QIAfilter Mega-Giga Cartridges (5)- Qiagen
711212010-FreeZone 12 Liter -84C Console Freeze Dryer- Labconco
9130010 10x/18mm WF eyepiece, focusable Labomed
HCB 1002 -Highland® Portable Precision Balances- Adam Equipment
D4074- Quick-DNA Microprep Plus Kit- Zymo Research 