The T9/T10DCS Spectrophotometer incorporates dual monochromator technology making it well suited to even the most demanding of applications in all areas of UV-Visible Spectroscopy.
The optical design of both the T9DCS and T10DCS offer extremely low stray light characteristics (≤0.00004%T NaI,220 nm) which allows for an extensive photometric range (-8.0 – 8.0Abs). Measurements at deep ultra-violet wavelengths can also be achieved with use of Nitrogen purged optics.
The instrument can be optically configured to suit the needs of the sample by means of a continually adjustable slit for precise control of spectral resolution and beam size adjustment by means of an attenuating wheel.
Key Features
- True Double Beam Double monochromator Optics, and fully sealed to provide ultra-low stray light (0.00004%%T @220nm) and high photometric range (-8.0~8.0 Abs)
- 185– 900nm Wavelength range with Nitrogen purge
- Precise Wavelength accuracy is ensured by the integrated Mercury lamp for automatic correction
- Continuously selectable spectra bandwidth from 0.1-5nm
- Beam size continuously adjustable for variety of applications including ultra-volume cuvettes
- Large sample compartment suitable for all kinds of accessories, especially for 150mm integrating sphere
- Support WIFI communication in field operation
- The integrated Mercury Emissions Lamp with automatic correction function ensures precise wavelength accuracy
| Model | T9DCS | T10DCS | |
| Optical system | Double beam | Double beam | |
| Scan speed | 1000 nm/min 1500 nm/min location speed |
1000 nm/min 1500 nm/min location speed |
|
| Wavelength range | 185-900 nm | 185-900 nm | |
| Wavelength accuracy | ±0.2 nm | ±0.2 nm | |
| Spectral bandwidth | ±20 % (0.1 nm-5 nm continuously adjustable) | ±20 % (0.1 nm-5 nm continuously adjustable) | |
| Photometric mode | Transmittance,Absorbance,Enegy and Concentration | Transmittance,Absorbance, Enegy and Concentration | |
| Photometric range | -6.0 Abs-6.0 Abs | -8.0 Abs-8.0 Abs | |
| Photometric accuracy | ±0.004 A@2.0 A ±0.003 A@1.0 A ±0.002 A@0.5 A ±0.3 % |
±0.004 A@2.0 A ±0.003 A@1.0 A ±0.002 A@0.5 A ±0.3 % |
|
| Photometric reproducibility | ≤0.002 A@2.0 A ≤0.0008 A/1.0 A ≤0.0004 A/0.5 A ≤0.1 % |
≤0.002 A@2.0 A ≤0.0008 A/1.0 A ≤0.0004 A/0.5 A ≤0.1 % |
|
| Photometric noise | 0 % Noise: ≤0.01 % 100 % Noise: ≤0.1 % |
0 % Noise: ≤0.01 % 100 % Noise: ≤0.1 % |
|
| Baseline flatness | ±0.0008 Abs | ±0.0005 Abs | |
| Baseline stability | 0.1 %/hr | 0.1 %/hr | |
| Stray light | ≤0.0001 %T (NaI, 220 nm) ≤0.0001 %T (NaNO2, 360 nm) |
≤0.00004 %T (NaI, 220 nm) ≤0.00002 %T (NaNO2, 360 nm) |
|
| Cell holder | Automatic 8 Cell Changer | Automatic 8 Cell Changer | |
| Detector | Photo multiplier tube | Photo multiplier tube | |
| Light source | D2 lamp,Tungstern lamp,Mercury lamp for WL correction | D2 lamp,Tungstern lamp,Mercury lamp for WL correction | |
| PC interface | RS232, USB, Wifi | RS232, USB, Wifi | |
| Software support | UV Win | UV Win | |
| Power supply | Switchable 120-230 VAC 50-60 Hz | Switchable 120-230 VAC 50-60 Hz | |
| Weight | 136 lb | 136 lb | |
| Dimensions (Width, Depth, Height) |
36 x 25 x 12 in | 36 x 25 x 12 in | |
| MODEL | PART NO | DESCRIPTION |
| T9DCS | T110+ | Double monochromater spectrometer with fixed cell holder, wavelength range 185-900nm with a user defined bandpass from 0.1-5.0nm in increments of 0.1nm. Stray light lower than 0.0001%T. PC controlled by USB or RS232 cable or WIFI |
| T10DCS | T112+ | Double monochromater spectrometer with fixed cell holder, wavelength range 185-900nm with a user defined bandpass from 0.1-5.0nm in increments of 0.1nm. Stray light lower than 0.00004%T. PC controlled by USB or RS232 cable or WIFI |
A-105177 Painted And Numbered 3-Part Life-Size Human Skull Axis Scientific
A-105173 Miniature Skull Axis Scientific
A-104271, 3-Part Life-Size Painted Didactic Human Skull Axis Scientific
0095F Fluorescent Pink Polypropylene Reversible 1.5ml And 2.0ml Microcentrifuge Tube Rack, 96 Places (Pack Of 5) Bio Plas
A-106193, Didactic Skull On Cervical Vertebrae With Nerves And Arteries Axis Scientific
A-105852 Classic Flexible Human Skeleton Axis Scientific
A-105940, 22 Part Osteopathic Natural Bone Human Skull Axis Scientific
A-104406 Complete Disarticulated Human Skeleton Axis Scientific
RE301C-OV - Rotary evaporator, Glass "C", Oil Bath, VR300RE301C-OV - Yamato
BSWNMR Block, 30 x NMR tubes Benchmark Scientific
911015119999 D2012 Plus High Speed Personal Micro-Centrifuge Scilogex
SF 3300- STAT FAX 3300- Awareness Technology
A-105168 Miniature Human Skeleton Axis Scientific
D4074- Quick-DNA Microprep Plus Kit- Zymo Research
RE801C-W- Rotary EvaporatorRE801C-W - Yamato
A-105867, Human Skull Model With Flexible Neck Axis Scientific
Q620 WashLab760 Laboratory Bottle Washer Kimadi
A-105759, Life-Size Human Skull With Removable Muscles Axis Scientific
A-105179, 22-Part Disarticulated Life-Size Human Skull Axis Scientific
A-105178, 3-Part Life-Size Human Skull With 8-Part Brain Axis Scientific
0091F Assorted Fluorescent Polypropylene Reversible 1.5ml And 2.0ml Microcentrifuge Tube Rack, 96 Places (Pack Of 5) Bio Plas
0094 Orange Polypropylene Reversible 1.5ml And 2.0ml Microcentrifuge Tube Rack, 96 Places (Pack Of 5) Bio Plas
BSW50 Block For Digital Dry Bath - 5 x 50ml Tubes Benchmark Scientific
840003 Digital Anemometer Thermometer Sper Scientific
A-105170 Miniature Painted Human Skeleton Axis Scientific
0092 Blue Polypropylene Reversible 1.5ml And 2.0ml Microcentrifuge Tube Rack, 96 Places (Pack Of 5) Bio Plas
A-105171 Half Disarticulated Human Skeleton Axis Scientific
SmartReader 96, Microplate Absorbance Reader Accuris
SF4200- Stat Fax®4200- Awareness Technology 