T7D/T7DS is a high performance double beam scanning spectrophotometer available with a variable spectral bandwidth, which is innovative in terms of instrument application, mechanical and optical design.
Electronic control and software enable this while maintaining features that are well established and accepted through the industry.
T7D/T7DS is able to carry out photometric measurements, spectrum scans, quantitative determinations and DNA/Protein analysis.When interfaced to a PC using the UV-Win software, many more features are available including three-dimensional spectrum, kinetic measurements, method and data storage, exportation of data in multiple formats and GLP administration features.
Key Features
- High performance variable spectral bandwidth
- Wavelength accuracy +/- 0.3nm
- Supplied with a motorized 8 cell changer and pre-aligned Tungsten and Deuterium lamps
- A number of optional accessories available to increase the flexibility of analysis
- High degree of automation requiring minimal key depressions to start analysis
- The simple mechanical structure and modular electrical design make the routine maintenance easy
| Specifications | ||
| Optical system | Double beam | |
| Scan speed | Selectable | |
| Wavelength range | 190-1100 nm | |
| Wavelength accuracy | ±0.3 nm | |
| Wavelength reproducibility | ≤0.2 nm | |
| Spectral bandwidth |
T7D: 2 nm T7DS: 0.5, 1.0, 2.0, 5.0 nm |
|
| Photometric mode | Transmittance, Absorbance, Energy Concentration | |
| Photometric range | -0.3-3.0 Abs | |
| Photometric accuracy | 0.002 A (0-0.5 A), 0.004 A (0.5-1 A), 0.3 %T (0-100 %T) | |
| Photometric reproducibility | 0.001 A(0-0.5 A), 0.002 A (0.5-1 A), 0.15 %T (0-100 %T) | |
| Photometric noise | 0.001 A (500 nm, 30 min warm-up) | |
| Baseline flatness | 0.0015 A (200-1000 nm) | |
| Baseline stability | 0.0008 A/h (500 nm, 0 Abs, 2 hrs warm-up) | |
| Stray light | ≤0.12 %T (220 nm NaI, 340 nm NaNO2) | |
| Standard functionality | Photometric, Quantitative, Spectrum and DNA measurements | |
| Cell holder | Automatic 8 cell changer | |
| Detector | Silicon photo diode | |
| Light source | Tungsten Halogen and Deuterium arc lamps | |
| Display | Digital LCD display | |
| Printer | Optional | |
| PC interface | RS232, USB | |
| Software support | Local and UV Win | |
| Power supply | Switch mode 120-230 VAC 50-60 Hz | |
| Weight | 80 lb | |
| Dimension | 28 x 24 x 20 in | |
| MODEL | PART NO | DESCRIPTION |
| T7D | 1810DAPC | Double beam UV-Vis Spectrometer, with 8 cell motorised holder, 190-1100mm, fixed 2nm bandwidth |
| T7S | 1810ASPC | Double beam UV-Vis Spectrometer, with 8 cell motorised holder, 190-1100nm, variable 0.5, 1, 2, 5nm bandwidth |
911015119999 D2012 Plus High Speed Personal Micro-Centrifuge Scilogex
SF4300- Stat Fax 4300 (Chromate)- Awareness Technology
A-104281 Painted Human Skeleton Axis Scientific
9010-0217 FED 400 UL Heating Chamber With Forced Convection Binder
SKM104- New Koharu - Elderly Patient Care Manikin- Sakamoto
GR126-500 - Sodium Dodecyl Sulfate (SDS) 500gr- Hoefer
A-105867, Human Skull Model With Flexible Neck Axis Scientific
A-104405, 3-Part Life-Size Human Skull Axis Scientific
RE601A-O - Rotary EvaporatorRE601A-O - Yamato
F123778-PIPETMAN Fixed F50, 50 µL-Gilson 