- Product No.SEG386Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typetissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.156-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.055ng/mL.
Specificity
This assay has high sensitivity and excellent specificity for detection of ATPase, Cu++ Transporting Beta Polypeptide (ATP7b).
No significant cross-reactivity or interference between ATPase, Cu++ Transporting Beta Polypeptide (ATP7b) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level ATPase, Cu++ Transporting Beta Polypeptide (ATP7b) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level ATPase, Cu++ Transporting Beta Polypeptide (ATP7b) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
911015119999 D2012 Plus High Speed Personal Micro-Centrifuge Scilogex
R1056- Quick-RNA Midiprep Kit 25 preps- Zymo Research
0095 Pink Polypropylene Reversible 1.5ml And 2.0ml Microcentrifuge Tube Rack, 96 Places (Pack Of 5) Bio Plas
V1002-S8 Optional eight channel adapter, fine tip stainless steel Accuris
711212110-FreeZone 12 Liter -84C Console Freeze Dryer- Labconco
A-105176 Disarticulated Half Child Skeleton Axis Scientific
0096 Well Microcentrifuge Tube Rack, Yellow, 5/Pk
D4074- Quick-DNA Microprep Plus Kit- Zymo Research
701811010-FreeZone 18 Liter -50C Console Freeze Dryer- Labconco
QIAamp DNA Blood Mini Kit (250) - 51106 - Qiagen
700402030- FreeZone 4.5 Liter -50C Benchtop Freeze Dryer- Labconco
A-105852 Classic Flexible Human Skeleton Axis Scientific
794801110-Stoppering Tray Dryer- Labconco
A-104270, 3-Part Life-Size Numbered Human Skull Axis Scientific
BSW50 Block For Digital Dry Bath - 5 x 50ml Tubes Benchmark Scientific
A-104272 Life-Size Human Skull With Blood Vessels Axis Scientific
Q620 WashLab760 Laboratory Bottle Washer Kimadi
A-105170 Miniature Painted Human Skeleton Axis Scientific
A-105171 Half Disarticulated Human Skeleton Axis Scientific
A-105868, Human Skull With Masticatory Muscles Axis Scientific
A-105168 Miniature Human Skeleton Axis Scientific 