Standard type of natural convec-tion constant temperature drying ovens, with extensive features and simple operation.
Performance and functions
- Economical and cost saving
- Easy to use and maintain
- Excellent temperature accuracy
- Digital PID controller for easy constant operation with options of Fixed setting
- Quick Auto Stop, Auto Start, Auto Stop operation
- Increased safety and self-diagnostic function
- Calibration off-set function
Safety features
- Temp sensor error, Temp input circuit error, Auto overheat prevention, Measured temp error, Circuit breaker with over current protection
| Model | DX302C DX312C |
DX402C DX412C |
DX602C DX612C |
| Circulation Method | Natural gravity convection | ||
| Operating temp. range | Room temp. +5°C to 300°C | Room temp. +5°C to 280°C | |
| Temperature Control Accuracy | ±1°C (at 300°C) | ||
| Temperature Distribution Accuracy | ±10°C (at 300°C) | ±10°C (at 280°C) | |
| Maximum Temperature Reaching Time | ~45 min (Room temp. to 300°C) | ~60 min (Room temp. to 300°C) | ~80 min (Room temp. to 280°C) |
| Interior Material | Stainless steel | ||
| Exterior Material | Electro-galvanized steel sheet with melamine resin baking finish | ||
| Heat Insulating Material | Glass wool | ||
| Heater | Iron-chrome wire heater 0.9 kW | Iron-chrome wire heater 1.36 kW | Iron-chrome wire heater 1.36 kW |
| Exhaust Port | 33 mm I.D. x 2 pcs. (on top) | ||
| Temp. Controller | PID control by microprocessor | ||
| Temp. Setting Method | Digital setting by ▲▼ key | ||
| Temp. Display Method | Measurement temp. : Digital display by green LED / Setting temp. : Digital display by red LED | ||
| Timer | 1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50 min. | ||
| Operation Function | Fixed temperature, Quick auto stop, Auto stop, Auto start | ||
| Additional Function | Calibration off-set, Power failure compensation function, Key lock function | ||
| Heater Circuit Control | SSR control | ||
| Sensor | K-thermocouple | ||
| Safety Device | Self diagnostic functions (Temp. Sensor abnormal, Abnormal memory, Input temp. abnormal, Measured temp. abnormal, Automatic overheat prevention), Key lock function, Hydraulic independent overheat prevention device, Electric leakage breaker with over current protection | ||
| Internal Dimensions W×D×H | 300x310x300mm | 450x410x400mm | 600x510x500mm |
| External Dimensions W×D×H | 400x440x630mm | 550x540x730mm | 700x640x830mm |
| Internal Capacity | 28L | 74L | 153L |
| Shelf Plate With Standard Load | 15kg/piece | 15kg/piece | 15kg/piece |
| Shelf Rest Step Number / Pitch | 6 steps / 35mm | 9 steps / 35mm | 12 steps / 35mm |
| Power Source 50/60Hz | AC115V 9.5A (with plug) AC220V 4.3A (no plug, round terminal) |
AC115V 14A (with plug) AC220V 6.4A (no plug, round terminal) |
AC115V 14A (with plug) AC220V 6.4A (no plug, round terminal) |
| Weight | ~23kg | ~38kg | ~56kg |
| External Dimensions W×D×H | 400x440x630mm | 550x540x730mm | 700x640x830mm |
PAA073MU01 -Anti-CD40 Mouse Monoclonal Antibody [clone: C7] -Cloud-Clone
PAQ975MU01 -Anti-S100A15 Rabbit Polyclonal Antibody -Cloud-Clone
PAB128HU01-Anti-SNRPD1 Rabbit Polyclonal Antibody- Cloude Clone
PAC862MU01-Anti-SNTb1 Rabbit Polyclonal Antibody- Cloude Clone
PH010P - M13KO7 Helper Phage (Pack 5 x 1 mL) -Antibody Design
PAB744HU01-Anti-UBD Rabbit Polyclonal Antibody-Cloud-Clone
PAB479HU01-Anti-HBEGF Rabbit Polyclonal Antibody- Cloude Clone
PAQ483HU01 -Anti-S100A15 Rabbit Polyclonal Antibody -Cloud-Clone
PAP859HU01-Anti-MXRA5 Rabbit Polyclonal Antibody- Cloude Clone
PAB230HU01-Anti-CTLA4 Rabbit Polyclonal Antibody- Cloude Clone
PAA013RA01-Anti-AMH Rabbit Polyclonal Antibody- Cloude Clone
P18R-MB - MICRO CENTRIFUGE – PURISPIN 18R – CRYSTE 