Description
Provided the room temperature is at least 23°C, the animal’s blood pressure can be measured without heating the animal. After photoplethysmographically measuring tail arterial blood pressure, pulses are stored in the computer memory and peak levels of the pulses are plotted on a display. Preheating of animals not required so thermal stress can be avoided
Overview
Provided the room temperature is at least 23°C, the animal’s blood pressure can be measured without heating the animal. After photoplethysmographically measuring tail arterial blood pressure, pulses are stored in the computer memory and peak levels of the pulses are plotted on a display.
Features
The 50370 Blood Pressure Monitor is perfect for measuring the effects of drugs on animals.
-
Use with animals under 10 grams
-
Use with C57 BL6 mice and colored mice
-
Use with Zucker Fatty Rats
-
Use with hamsters (with a leg cuff anesthetic)
-
The only monitor that can be used with guinea pigs — even without anesthesia!
-
The only monitor that can be used with OB (diabetic model) mice
| Specifications | |
| Mean Blood Pressure (MBP) | Cuff pressure when pulse amplitude becomes largest |
| Diastolic Blood Pressure (DBP) | Calculated value based on SBP and MBP (3MBP-SBP)/2 |
| Detection | LED, Photo Transistor |
| Inflation Range | 0 – 350mmHg |
| Printer Outputs | Date, Time, Animal No., Weight, Operation Mode, Interval, No of Measuring Trials, Raw Data, Average and S.D. |
| Chart Paper | Thermo-sensitive 58 mm Wide x 25m Long |
| Power | 110-240V, 50/60hz |
| Dimensions | 210W x 310D x 210 mmH |
| Weight | Approx. 8 kg |
Detail
Easy Operation
-
Two operation modes are available
-
Mode 1: HR (Heart Rate) and SBP (Systolic Blood Pressure)
-
Mode 2: HR, SBP, MBP (Mean Blood Pressure) and DBP (Diastolic Blood Pressure, calculated value) can be measured.
-
-
Continuous measurement can be performed up to ten (10) times.
-
Rapid Printout Function
-
Colored mice such as C57BL/6, neonatal mice, hamsters (anesthetized) and guinea pigs (non-anesthetized) can be measured.
-
Sick animals can be measured. (e.g. animal with cardiac infarction)
-
Multi-channel system is no longer needed. Just prepare multiple restrainers, and measurement can be done one after the other.
-
Auto-Sequence Function blood pressure of a tail artery of an animal can be monitored automatically at specified time intervals, which can be 1-99 minutes in length.
-
Time-Stamp Function
-
Hard Copy Function
-
An RS-232C interface is provided on the rear panel of the main unit. Using the optional Data Collection Software (Windows Version) the data obtained can be exported to a personal computer and stored as a CSV file.
-
The animal holders are made of dark brown acrylic, allowing BP measurement under relatively stress-free conditions.
-
Operation is very simple
Included Accessories
Includes: Built-in Printer, 9″ Display, Measuring Stand, choice of Cuff- Pulse Sensor, choice of Animal Holder, and 5 rolls of Thermo Chart Paper. A high-speed Thermal Printer, integral to the instrument, is also included.
For PC compatibility, Data Collection Software (50391), is necessary.
H5000-02 Block, 96 x 0.2ml or 1 x PCR plate Benchmark Scientific
FA10004P-PIPETMAN L P100L, 10-100 µL, Plastic Ejector-Gilson
RE801A-W- Rotary EvaporatorRE801A-W - Yamato
RE301C-W - Rotary evaporator, Glass "C", Water BathRE301C-W - Yamato
VE-B10 PHASE CONTRAST MICROSCOPE - VELAB
VE-B2 BASIC BINOCULAR MICROSCOPE - VELAB
VE-B7 INTERMEDIATE BINOCULAR MICROSCOPE - VELAB
M-FEED-P -CORE SYSTEM consists of 4 items: bottom, lid, water, and feeder. Each item purchased separately. Mouse Feeders, Plastic Mouse Feeder (PET, no grate) - Innovive
911015119999 D2012 Plus High Speed Personal Micro-Centrifuge Scilogex
M-BTM -CORE SYSTEM consists of 4 items: bottom, lid, water, and feeder. Each item purchased separately. Mouse Feeders, Standard Mouse Feeder, extended-Use (PS, zinc plated steel insert grate) - Innovive
RVX5 - Rat Caging, Innocage® Lids External Water Bottle, Autowatering Innocage® IVC Rat Dual Filter - Innovive
GR142-100 -N,N’ - Methylene-bis-Acrylamide 100gr- Hoefer
E1101-CS2 Casting Set for 5 x 6 cm gels; Includes 4 trays and 2 combs (18*/10 teeth) Accuris
12-500- Omni THQ - Digital Tissue Homogenizer- Omni International
H38878-0010, DRY ICE MAKER; U.S. MODEL, 12 X 6½ X 5 IN. Bel-Art
VE-M3-BIOLOGICAL MONOCULAR MICROSCOPE -VELAB
WE200 - Water Purifier (RO + Ion-exchange)WE200- Yamat
F144055M-PIPETMAN G P10G, 1-10 µL, Metal Ejector-Gilson
9126200 Binocular Observation Head Labomed
F123770-PIPETMAN Fixed F2, 2 µL-Gilson
74104-RNeasy Mini Kit (50)- Qiagen
88870108, Digital and Touchscreen Dry Bath Accessories Thermo Scientific-8 x 20mm dia. Block
FP-303 - High Performance Muffle Furnace 7.5L 115V- Yamato
D4204 - ZymoPURE II Plasmid Gigaprep Kit 5 Preps- Zymo Research
H5000-05 Block, 54 x 0.5ml Benchmark Scientific
YS3020, Color Spectrophotometer with Customized Aperture 3nh
19-042E- Bead Ruptor Elite - Omni International
F144056M-PIPETMAN G P20G, 2-20 µL, Metal Ejector-Gilson
H5000-1232 Block, 24 x 2ml AutoSample (HPLC) vials (12x32mm) Benchmark Scientific
SPB 2103i -Solis Precision Balances- Adam Equipment
FP-103 - High Performance Muffle Furnace 1.5L 115V- Yamato
RE801C-W- Rotary EvaporatorRE801C-W - Yamato
R1002-YeaStar RNA Kit 40 Preps- Zymo Research
F123789-PIPETMAN Fixed F400, 400 µL-Gilson 