The Enhancer 3000 Monitoring System allows researchers to maintain efficiencies, optimize both electrical and biological parameters, view sample runs, troubleshoot possible problems and easily perform routine quality control. Communications using the USB data port permits storage and documentation of data for further analysis.
The Enhancer 3000 simply interfaces between the generator and the electroporation chamber (safety stand or BTX electroporation plate handler). In addition, the optional communications module allows the user to send the waveform information directly to a printer or a computer.
Key Features
- Confirms and tracks all key electroporation parameters including waveform, pulse lengths, peak amplitude, pulse intervals, field strength, and AC duration
- Monitors all waveforms for optimization or troubleshooting of electroporation parameters
- Facilitates calculation of field strength, pulse length, pulse duration or frequency
- Safe connections protect user from exposure to high voltage
- Optional Communications Module offers standard printer and computer interface
| Enhancer 3000 High Voltage Probe Specifications | |
| Attenuation | 1:100 / 1:1000 |
| Bandwidth | DC to 70 MHz (-3 dB) |
| Accuracy | +/-2% |
| Input Impedance | 10 M Ω// 10 pF each side to ground |
| Input Voltage: | |
| Differential Range | +/-700 V (DC+Peak AC) or 700 Vrms @ 1/100 +/-7000 V (DC+Peak AC) or 5000 Vrms @ 1/1000 |
| Common Mode Range | +/-7000 V (DC+Peak AC) or 2500 Vrms @ 1/100 & 1/1000 |
| Absolute Max. Range | 1 ±7000 V (DC+Peak AC) or 2500 Vrms @ 1/100 & 1/1000 in common mode ±7000 V (DC+Peak AC) or 5000 Vrms @ 1/100 & 1/1000 in differential mode |
| Output Voltage: | |
| Max. Amplitude | +/-7 V (into 50k ohm load) |
| Offset (typical) | < +/-5 mV |
| Noise (typical) | 0.9 mVrms |
| Source Impedance (typical) | 50 Ω |
| CMRR (typical) | -80 dB @ 60 Hz, -50 dB @ 1 MHz |
| Operating Temperature | -10 to 40°C |
| Ambient Storage Temperature | -30° to 70°C |
| Operating Humidity | 25 to 85% RH |
| Ambient Storage Humidity | 25 to 85% RH |
| Pollution Degree | 2 (Not to be operated in conductive pollutants atmosphere |
| Power Requirements: | |
| Standard | 4 AA cells or optional mains adapter or regulated 9 VDC/120mA mains adapter |
| Length of BNC Cable | 88.9 cm (35 in) |
| Length of Input | Leads 30.48 cm (12 in) |
| Weight | 454 g (1 lb) |
| Dimensions (L x W x H) | 20.3 x 8.3 x 3.8 cm (8″ x 3.25 x 1.5 in) |
Notes: 1. Voltage limit isthe lesser of the DC + Peak AC and RMS values. 2. a. The supplied voltage must be lessthan 12 V and greater than 4.4 V, otherwise the probe
could be damaged or will not operate properly. b. Polarityis“+”inside and “-” outside.For wrong polarity, a built-in circuit protectsthe probe; no danger or damage will occur.c. When the voltage of the batteries become too low, the power indicator will flicker.
| Voltage Interface Box Specifications | |
| Input, Output, Probe Connections: | |
| Type | 4 mm Banana Jack |
| Voltage | 2500 Vrms, 3500 Vpk CAT II |
| Current (Max. Continuous) | 15 A |
| Current (Peak) | 1000 A for 100 µs |
| Dimensions (L x W x H) | 13.5 cm x 13.5 cm x 5.8 cm (5.3 x 5.3 x 2.3 in) |
| High Voltage Cable Specifications | |
| Type | Retractable Sheath Banana Plug |
| Length | 91.44 cm (3 ft) |
| Wire Gauge | 18 AWG |
| Insulation | PVC |
| Voltage Rating | 1000 Vrms IEC 1010-2-31, Category III |
| Current | 10 A |
| Operating Temperature | +55º C (+131º F) Max. |
MAB990HU21 - Anti-TLR5 Mouse Monoclonal Antibody [clone: 8-1#] -Cloud-Clone
HW-MR3-Humaneway Mice Restraint Device SIze 35- Hundred
R-BTMA-H -Rat Caging, Innocage® Bottom, Autowatering cage bottom, empty - Innovive
3970424- 4' Purifier Vertical Clean Bench with UV Light, Protection Panel and Airflow Monitor- Labconco
HW-RR2-Humaneway Rat Restraint Device SIze 64- Hundred
HW-MR2-Humaneway Mice Restraint Device SIze 32- Hundred
HW-RR1-Humaneway Rat Restraint Device SIze 47- Hundred
HW-MSWK-Humaneway Mouse Tail Vein Simulator (W)- Hundred
07-07200 - Multi-Gen Adapter (Required for Multi-Gen 7XL Probes)- PRO Scientific
M-BTM -CORE SYSTEM consists of 4 items: bottom, lid, water, and feeder. Each item purchased separately. Mouse Feeders, Standard Mouse Feeder, extended-Use (PS, zinc plated steel insert grate) - Innovive
BSH100-CV Block. 8 x cuvettes (not compatible with cover) Benchmark Scientific
BSH100-500 Block, 2 x 50ml Benchmark Scientific
PAA077MU01 -Anti-IL4 Rabbit Polyclonal Antibody -Cloud-Clone
A-105176 Disarticulated Half Child Skeleton Axis Scientific
0094 Orange Polypropylene Reversible 1.5ml And 2.0ml Microcentrifuge Tube Rack, 96 Places (Pack Of 5) Bio Plas
QIAamp DNA Blood Mini Kit (250) - 51106 - Qiagen
R1056- Quick-RNA Midiprep Kit 25 preps- Zymo Research
HW-RR3-Humaneway Rat Restraint Device SIze 70- Hundred
PTM 500 Drum and Wheelchair Platforms Adam Equipment
PAC862MU01-Anti-SNTb1 Rabbit Polyclonal Antibody- Cloude Clone
HW-MSWK10-Humaneway Set of 10 Mouse Tail Vein Simulators (W)- Hundred
911015119999 D2012 Plus High Speed Personal Micro-Centrifuge Scilogex
FA10031-PIPETMAN L Fixed F5000L, 5000 µL-Gilson
D4075- Quick-DNA Midiprep Plus Kit- Zymo Research
GR146-1 -5X TBE Buffer 1LT- Hoefer
RVX5 - Rat Caging, Innocage® Lids External Water Bottle, Autowatering Innocage® IVC Rat Dual Filter - Innovive
0713-00 Multi-Torso - Male Only - Male Only- Denoyer-Geppert
HW-MSBK-Humaneway Mouse Tail Vein Simulator (B)- Hundred
M152-1- Intramuscular Injection Model of Buttocks Type 2- Sakamoto
PK-01200D - Deluxe Micro-Homogenizer Package - PRO Scientific 