Product Details
The QIAquick Gel Extraction Kit provides spin columns, buffers, and collection tubes for silica-membrane-based purification of DNA fragments from gels (up to 400 mg slices) or enzymatic reactions. DNA ranging from 70 bp to 10 kb is purified using a simple and fast bind-wash-elute procedure and an elution volume of 30–50 μl. An integrated pH indicator allows easy determination of the optimal pH for DNA binding to the spin column. The procedure can be fully automated on the QIAcube Connect.
For optimal results it is recommended to use this product together with QIAvac 24 Plus.
Performance
The QIAquick Gel Extraction Kit enables removal of nucleotides, enzymes, salts, agarose, ethidium bromide, and other impurities from samples, ensuring up to 80% recovery of DNA (see figure ” High recoveries from gels”). Using a microcentrifuge or vacuum manifold, DNA ranging from 70 bp to 10 kb is purified from 1–24 samples. Purified DNA can be used, for example, in sequencing (see figure ” Reliable sequencing after gel extraction”). DNA fragments smaller than 70 bp or larger than 10 kb should be extracted with the QIAEX II Gel Extraction System.
Principle
QIAquick Kits contain a silica membrane assembly for binding of DNA in high-salt buffer and elution with low-salt buffer or water. The purification procedure removes primers, nucleotides, enzymes, mineral oil, salts, agarose, ethidium bromide, and other impurities from DNA samples (see figure ” High recoveries from gels”). Silica-membrane technology eliminates the problems and inconvenience associated with loose resins and slurries. Specialized binding buffers are optimized for specific applications and promote selective adsorption of DNA molecules within particular size ranges.
Gel loading dye
To enable faster and more convenient sample processing and analysis, gel loading dye is provided. GelPilot Loading Dye contains three tracking dyes (xylene cyanol, bromophenol blue, and orange G) to facilitate the optimization of agarose gel run time and prevent smaller DNA fragments migrating too far (see figure “GelPilot Loading Dye”).
Procedure
The QIAquick system uses a simple bind-wash-elute procedure (see flowchart ” QIAquick and MinElute procedure”). Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the QIAquick spin column (see figure ” pH Indicator Dye”). Nucleic acids adsorb to the silica membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in all subsequent applications.
Handling
QIAquick spin columns are designed to provide two convenient handling options. The spin columns fit into a conventional table-top microcentrifuge or onto any vacuum manifold with luer connectors, such as the QIAvac 24 Plus with QIAvac Luer Adapters. The QIAquick Gel Extraction Kit, in addition to other QIAGEN spin-column-based kits, can be fully automated on the QIAcube, enabling increased productivity and standardization of results (see figures “Spin column handling options A, B, C, D, and E”).
Applications
DNA fragments purified with the QIAquick system are ready for direct use in all applications, including sequencing, ligation and transformation, restriction digestion, labeling, microinjection, PCR, and in vitro transcription.
| Features | Specifications |
| Binding capacity | 10 µg |
| Format | Tube |
| Fragment size | 70 bp – 10 kb |
| Recovery: oligonucleotides dsDNA | Recovery: dsDNA fragments |
| Processing | Manual |
| Removal <10mers 17–40mers dye terminator proteins | Removal <10mers |
| Elution volume | 30–50 µl |
| Technology | Silica technology |
| Sample type: applications | DNA: PCR reactions |
0713-00 Multi-Torso - Male Only - Male Only- Denoyer-Geppert
18020 -JVP Spatial Discrimination Domes- Stoelting
CNA-TACH-DHH7-Hand Held Tachometer- LW Scientific
SAB 125i -Solis Semi-Micro and Analytical Balances- Adam Equipment
F144073-PIPETMAN G Multichannel P12x200G, 20-200µL-Gilson
3970205- 2' Purifier Filtered PCR Enclosure with UV Light, Protection Panel and Airflow Monitor- Labconco
0099 Black Polypropylene Reversible 1.5ml And 2.0ml Microcentrifuge Tube Rack, 96 Places (Pack Of 5) Bio Plas
VE-M3-BIOLOGICAL MONOCULAR MICROSCOPE -VELAB
4318 Polypropylene 0.5ml Graduated Flat Top Microcentrifuge Tube,Blue Bio Plas
9130010-202 Pair of eyeguards for eyepieces Labomed
701812130-FreeZone 18 Liter -50C Console Freeze Dryer- Labconco
VE-B1 BIOLOGICAL BINOCULAR MICROSCOPE - VELAB
FA10027-PIPETMAN L Fixed F300L, 300 µL-Gilson
PTM 500 Drum and Wheelchair Platforms Adam Equipment
FA10026-PIPETMAN L Fixed F250L, 250 µL-Gilson
S67F Premier Flexible Series Skeleton - Suspension - Painted, Number-Coded - Fema- Denoyer Geppert
A00000001, Derivation element PW 10 Velp
SKM104- New Koharu - Elderly Patient Care Manikin- Sakamoto
VE-B4 INTERMEDIATE BINOCULAR MICROSCOPE - VELAB
3970221- 2' Purifier Vertical Clean Bench with UV Light and Protection Panel- Labconco
LPB 823e -Luna Precision Balances- Adam Equipment
NS800, Spectrophotometer 3nh
BCLO3011 Bar Code Cards Place X 10 Alliance Bio Expertise
NBL 12001P -Nimbus® Precision Balances- Adam Equipment
701212110- FreeZone 12 Liter -50C Console Freeze Dryer- Labconco
06-209-05 - 5 Ml Omni Prep Tube Holder- Omni International
SF2200- Stat Fax®2200- Awareness Technology
3970420- 4' Purifier Vertical Clean Bench- Labconco
VE-M6 BIOLOGICAL MONOCULAR MICROSCOPE - VELAB
701821010-FreeZone 18 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
700202030- FreeZone 2.5 Liter -50C Benchtop Freeze Dryer- Labconco
A-105852 Classic Flexible Human Skeleton Axis Scientific
800G 1-Liter with Glass Container Waring
BSH100-15 Block, 15 x 1.5ml Benchmark Scientific
3970320- 3' Purifier Vertical Clean Bench- Labconco
88870119, Digital and Touchscreen Dry Bath Accessories Thermo Scientific-50mL Conical Tube Block
711221110-FreeZone 12 Liter -84C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
F144057M-PIPETMAN G P100G, 10-100 µL, Metal Ejector-Gilson
WashLab790 Laboratory Bottle Washer Kimadi
F144066-PIPETMAN G P5000G, 500-5000 µL-Gilson
F144069-PIPETMAN G Multichannel P12x10G, 1-10µL-Gilson 



