Product Details
The QIAquick Gel Extraction Kit provides spin columns, buffers, and collection tubes for silica-membrane-based purification of DNA fragments from gels (up to 400 mg slices) or enzymatic reactions. DNA ranging from 70 bp to 10 kb is purified using a simple and fast bind-wash-elute procedure and an elution volume of 30–50 μl. An integrated pH indicator allows easy determination of the optimal pH for DNA binding to the spin column. The procedure can be fully automated on the QIAcube Connect.
For optimal results it is recommended to use this product together with QIAvac 24 Plus.
Performance
The QIAquick Gel Extraction Kit enables removal of nucleotides, enzymes, salts, agarose, ethidium bromide, and other impurities from samples, ensuring up to 80% recovery of DNA (see figure ” High recoveries from gels”). Using a microcentrifuge or vacuum manifold, DNA ranging from 70 bp to 10 kb is purified from 1–24 samples. Purified DNA can be used, for example, in sequencing (see figure ” Reliable sequencing after gel extraction”). DNA fragments smaller than 70 bp or larger than 10 kb should be extracted with the QIAEX II Gel Extraction System.
Principle
QIAquick Kits contain a silica membrane assembly for binding of DNA in high-salt buffer and elution with low-salt buffer or water. The purification procedure removes primers, nucleotides, enzymes, mineral oil, salts, agarose, ethidium bromide, and other impurities from DNA samples (see figure ” High recoveries from gels”). Silica-membrane technology eliminates the problems and inconvenience associated with loose resins and slurries. Specialized binding buffers are optimized for specific applications and promote selective adsorption of DNA molecules within particular size ranges.
Gel loading dye
To enable faster and more convenient sample processing and analysis, gel loading dye is provided. GelPilot Loading Dye contains three tracking dyes (xylene cyanol, bromophenol blue, and orange G) to facilitate the optimization of agarose gel run time and prevent smaller DNA fragments migrating too far (see figure “GelPilot Loading Dye”).
Procedure
The QIAquick system uses a simple bind-wash-elute procedure (see flowchart ” QIAquick and MinElute procedure”). Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the QIAquick spin column (see figure ” pH Indicator Dye”). Nucleic acids adsorb to the silica membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in all subsequent applications.
Handling
QIAquick spin columns are designed to provide two convenient handling options. The spin columns fit into a conventional table-top microcentrifuge or onto any vacuum manifold with luer connectors, such as the QIAvac 24 Plus with QIAvac Luer Adapters. The QIAquick Gel Extraction Kit, in addition to other QIAGEN spin-column-based kits, can be fully automated on the QIAcube, enabling increased productivity and standardization of results (see figures “Spin column handling options A, B, C, D, and E”).
Applications
DNA fragments purified with the QIAquick system are ready for direct use in all applications, including sequencing, ligation and transformation, restriction digestion, labeling, microinjection, PCR, and in vitro transcription.
| Features | Specifications |
| Binding capacity | 10 µg |
| Format | Tube |
| Fragment size | 70 bp – 10 kb |
| Recovery: oligonucleotides dsDNA | Recovery: dsDNA fragments |
| Processing | Manual |
| Removal <10mers 17–40mers dye terminator proteins | Removal <10mers |
| Elution volume | 30–50 µl |
| Technology | Silica technology |
| Sample type: applications | DNA: PCR reactions |
F110123-2ML Serological Pipette BulkSt 40 bags of 25-Gilson
EC-5108A Evatros C(200ml Tube, 8 Hole) + Evatros G (200L/min Dry Air) Goojung
710611100-FreeZone 6 Liter -84C Console Freeze Dryer- Labconco
NS820, Small Aperture Spectrophotometer with 4mm Aperture 3nh
88870116, Digital and Touchscreen Dry Bath Accessories Thermo Scientific- 15mL Flat-Bottom Tube Block
0091F Assorted Fluorescent Polypropylene Reversible 1.5ml And 2.0ml Microcentrifuge Tube Rack, 96 Places (Pack Of 5) Bio Plas
A-105177 Painted And Numbered 3-Part Life-Size Human Skull Axis Scientific
3970405- 4' Purifier Filtered PCR Enclosure with UV Light, Protection Panel and Airflow Monitor- Labconco
EAB 414i -Equinox Semi-Micro and Analytical Balances- Adam Equipment
3970223- 2' Purifier Vertical Clean Bench with Airflow Monitor- Labconco
A-105862, Neck and Throat Model with Muscles, Veins and Arteries Axis Scientific
BSH100-CV Block. 8 x cuvettes (not compatible with cover) Benchmark Scientific
A-105852 Classic Flexible Human Skeleton Axis Scientific
F110128-10ML Serological Pipette 200 Individually wrapped-Gilson
F81052-PIPETMAN M P8X100M BT Connected-Gilson
710402000-FreeZone 4.5 Liter -84C Benchtop Freeze Dryer- Labconco
06-207 - Cooling Ice Tray - For 2 Ml - 5 Ml Tubes- Omni International
700621030- FreeZone 6 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
701222110- FreeZone 12 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
R1056- Quick-RNA Midiprep Kit 25 preps- Zymo Research 



