Product Details
The QIAquick Gel Extraction Kit provides spin columns, buffers, and collection tubes for silica-membrane-based purification of DNA fragments from gels (up to 400 mg slices) or enzymatic reactions. DNA ranging from 70 bp to 10 kb is purified using a simple and fast bind-wash-elute procedure and an elution volume of 30–50 μl. An integrated pH indicator allows easy determination of the optimal pH for DNA binding to the spin column. The procedure can be fully automated on the QIAcube Connect.
For optimal results it is recommended to use this product together with QIAvac 24 Plus.
Performance
The QIAquick Gel Extraction Kit enables removal of nucleotides, enzymes, salts, agarose, ethidium bromide, and other impurities from samples, ensuring up to 80% recovery of DNA (see figure ” High recoveries from gels”). Using a microcentrifuge or vacuum manifold, DNA ranging from 70 bp to 10 kb is purified from 1–24 samples. Purified DNA can be used, for example, in sequencing (see figure ” Reliable sequencing after gel extraction”). DNA fragments smaller than 70 bp or larger than 10 kb should be extracted with the QIAEX II Gel Extraction System.
Principle
QIAquick Kits contain a silica membrane assembly for binding of DNA in high-salt buffer and elution with low-salt buffer or water. The purification procedure removes primers, nucleotides, enzymes, mineral oil, salts, agarose, ethidium bromide, and other impurities from DNA samples (see figure ” High recoveries from gels”). Silica-membrane technology eliminates the problems and inconvenience associated with loose resins and slurries. Specialized binding buffers are optimized for specific applications and promote selective adsorption of DNA molecules within particular size ranges.
Gel loading dye
To enable faster and more convenient sample processing and analysis, gel loading dye is provided. GelPilot Loading Dye contains three tracking dyes (xylene cyanol, bromophenol blue, and orange G) to facilitate the optimization of agarose gel run time and prevent smaller DNA fragments migrating too far (see figure “GelPilot Loading Dye”).
Procedure
The QIAquick system uses a simple bind-wash-elute procedure (see flowchart ” QIAquick and MinElute procedure”). Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the QIAquick spin column (see figure ” pH Indicator Dye”). Nucleic acids adsorb to the silica membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in all subsequent applications.
Handling
QIAquick spin columns are designed to provide two convenient handling options. The spin columns fit into a conventional table-top microcentrifuge or onto any vacuum manifold with luer connectors, such as the QIAvac 24 Plus with QIAvac Luer Adapters. The QIAquick Gel Extraction Kit, in addition to other QIAGEN spin-column-based kits, can be fully automated on the QIAcube, enabling increased productivity and standardization of results (see figures “Spin column handling options A, B, C, D, and E”).
Applications
DNA fragments purified with the QIAquick system are ready for direct use in all applications, including sequencing, ligation and transformation, restriction digestion, labeling, microinjection, PCR, and in vitro transcription.
| Features | Specifications |
| Binding capacity | 10 µg |
| Format | Tube |
| Fragment size | 70 bp – 10 kb |
| Recovery: oligonucleotides dsDNA | Recovery: dsDNA fragments |
| Processing | Manual |
| Removal <10mers 17–40mers dye terminator proteins | Removal <10mers |
| Elution volume | 30–50 µl |
| Technology | Silica technology |
| Sample type: applications | DNA: PCR reactions |
F110130-25ML Serological Pipette 200 Individually wrapped-Gilson
A-104286, 27-Part Dual-Sex Life-Size Torso with Open Back Axis Scientific
FA10009-PIPETMAN L Multichannel P8x20L, 2-20 µL-Gilson
A-105176 Disarticulated Half Child Skeleton Axis Scientific
711211010-FreeZone 12 Liter -84C Console Freeze Dryer- Labconco
F110121-1ML Serological Pipette BulkSt 40 bags of 25-Gilson
9010-0217 FED 400 UL Heating Chamber With Forced Convection Binder
A-104281 Painted Human Skeleton Axis Scientific
BSH100-CV Block. 8 x cuvettes (not compatible with cover) Benchmark Scientific
QIAamp DNA Blood Mini Kit (250) - 51106 - Qiagen
EC-3324-E Endpoint Block 24 Hole 30mm - 50mL 1ea-Non Hole Goojung
700611030- FreeZone 6 Liter -50C Console Freeze Dryer- Labconco
MAA133Hu22-Anti-TNFa Mouse Monoclonal Antibody [clone: C1]- Cloude Clone
EC-1048-E Eppendorf Block-48 Hole 10.8mm-2mL 2/pk-Non Hole, Tip Goojung
EZ-190F - Auto Flow Vaporizer Machine - E-Z Systems
81-12531-00, Omega Fluor™ Plus Gel Documentation System, 365 nm Gel Company
LBB 8001e -Luna Precision Balances- Adam Equipment
FA10002P-PIPETMAN L P10L, 1-10 µL, Plastic Ejector-Gilson
GR146-1 -5X TBE Buffer 1LT- Hoefer
F81058-PIPETMAN M P8X1200M BT Connected-Gilson
711212010-FreeZone 12 Liter -84C Console Freeze Dryer- Labconco
710201010-FreeZone 2.5 Liter -84C Benchtop Freeze Dryer- Labconco
701222130- FreeZone 12 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
701221130- FreeZone 12 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
710402000-FreeZone 4.5 Liter -84C Benchtop Freeze Dryer- Labconco
F123601-PIPETMAN Classic P200-Gilson
3970402- 4' Purifier Filtered PCR Enclosure with UV Light and Protection Panel- Labconco
3970303- 3' Purifier Vertical Clean Bench with Airflow Monitor- Labconco
88870113, Digital and Touchscreen Dry Bath Accessories Thermo Scientific-Mixed Block, 1.5mL and 2.0mL
FA10026-PIPETMAN L Fixed F250L, 250 µL-Gilson
AZI400-Azure 400-Azure BioSystems
FA10006M-PIPETMAN L P1000L, 100-1000 µL, Metal Ejector-Gilson
840003 Digital Anemometer Thermometer Sper Scientific
C8306-PowerSpin™ HX Centrifuge- Unico
F81057-PIPETMAN M P12X300M BT Connected-Gilson
FA10019-PIPETMAN L Fixed F5L, 5 µL-Gilson
A-105163, Flexible Elbow Joint Axis Scientific
3970202- 2' Purifier Filtered PCR Enclosure with UV Light and Protection Panel- Labconco
4304 Polypropylene 1.5ml Graduated Flat Top Microcentrifuge Tube, Green Bio Plas
BSWPCR1 Block, 1 x 96-well PCR plate (Single block model only) Benchmark Scientific
632543-Antibodies to detect orange fluorescent proteins: mOrange2- Takara
F81055-PIPETMAN M P12X200M BT Connected-Gilson
F144056M-PIPETMAN G P20G, 2-20 µL, Metal Ejector-Gilson 


