T8DCS is a high performance double beam spectrophotometer with a continuously selectable spectral bandwidth from 0.1-5nm.
It meets various demands for spectral bandwidth from users in different industries especially pharmaceutical industry and scientic research field.
The Czerny-Turner Monochromator with a holographic grating keeps stray light to a minimum and offers excellent optical resolution.
The use of a photomultiplier tube as detector delivers exceptional sensitivity.
The T8DCS’ true double-beam optical system coupled with an efficient and well proven electronic control system ensures high stability and low background noise.
Key Features
- A high-performance double beam spectrophotometer with a variable spectral bandwidth from 0.1-5nm, selected by a continuous changeable slit
- User friendly design allows easy light source replacement and routine maintenance
- Large sample compartment design enables use of a wide range of accessories
| Specifications | ||
| Optical system | Double beam | |
| Scan speed | Selectable | |
| Wavelength range | 190-900 nm | |
| Wavelength accuracy | ±0.3 nm | |
| Wavelength reproducibility | ≤0.1 nm | |
| Spectral bandwidth |
0.1 – 5 nm Continually Adjustable |
|
| Photometric mode | Transmittance, Absorbance, Energy Concentration, all using UVWin software | |
| Photometric range | -4.0-4.0 Abs | |
| Photometric accuracy | 0.002 A (0-0.5 A), 0.004 A (0.5-1 A), 0.3 %T (0-100 %T) | |
| Photometric reproducibility | 0.001 A (0-0.5 A) | |
| Photometric noise | 0.0004 A (500 nm, 30 min warm-up) | |
| Baseline flatness | 0.001 A (200-850 nm) | |
| Baseline stability | 0.0008 A/h (500 nm, 0 Abs, 2hrs warm-up) | |
| Stray light | ≤0.01 %T (220 nm NaI, 340 nm NaNO2) | |
| Standard functionality | No stand alone function | |
| Cell holder | Fixed position sample and reference | |
| Detector | Photo multiplier tube | |
| Light source | Tungsten Halogen and Deuterium arc lamps | |
| Display | No display | |
| Printer | Not available | |
| PC interface | RS232, USB | |
| Software support | UV Win | |
| Power supply | Switch mode 120-230 VAC 50-60 Hz | |
| Weight | 95 lb | |
| Dimension | 21.5 x 23 x 11 in | |
| MODEL | PART NO | DESCRIPTION |
| T8DCS | 1950 | Double beam Spectrometer with fixed cell holder, wavelength range 190-900nm with a user defined bandpass from 0.1-5.0nm in increments of 0.1nm. PC controlled by USB or RS232 cable. |
A-105176 Disarticulated Half Child Skeleton Axis Scientific
A-104267 Classic Human Skeleton With Study & Numbering Guide Axis Scientific
Q620 WashLab760 Laboratory Bottle Washer Kimadi
A-105168 Miniature Human Skeleton Axis Scientific
A-105177 Painted And Numbered 3-Part Life-Size Human Skull Axis Scientific
AW-62 Automatic Laboratory Glassware Washer 115V/220V Yamato
A-105940, 22 Part Osteopathic Natural Bone Human Skull Axis Scientific
A-105170 Miniature Painted Human Skeleton Axis Scientific
F144802-PIPETMAN Classic P10-Gilson
F81048-PIPETMAN M P8X10M BT Connected-Gilson
A-105179, 22-Part Disarticulated Life-Size Human Skull Axis Scientific
A-105171 Half Disarticulated Human Skeleton Axis Scientific
V1002 Handheld vacuum controller with single channel adapters Accuris 