T8DCS is a high performance double beam spectrophotometer with a continuously selectable spectral bandwidth from 0.1-5nm.
It meets various demands for spectral bandwidth from users in different industries especially pharmaceutical industry and scientic research field.
The Czerny-Turner Monochromator with a holographic grating keeps stray light to a minimum and offers excellent optical resolution.
The use of a photomultiplier tube as detector delivers exceptional sensitivity.
The T8DCS’ true double-beam optical system coupled with an efficient and well proven electronic control system ensures high stability and low background noise.
Key Features
- A high-performance double beam spectrophotometer with a variable spectral bandwidth from 0.1-5nm, selected by a continuous changeable slit
- User friendly design allows easy light source replacement and routine maintenance
- Large sample compartment design enables use of a wide range of accessories
| Specifications | ||
| Optical system | Double beam | |
| Scan speed | Selectable | |
| Wavelength range | 190-900 nm | |
| Wavelength accuracy | ±0.3 nm | |
| Wavelength reproducibility | ≤0.1 nm | |
| Spectral bandwidth |
0.1 – 5 nm Continually Adjustable |
|
| Photometric mode | Transmittance, Absorbance, Energy Concentration, all using UVWin software | |
| Photometric range | -4.0-4.0 Abs | |
| Photometric accuracy | 0.002 A (0-0.5 A), 0.004 A (0.5-1 A), 0.3 %T (0-100 %T) | |
| Photometric reproducibility | 0.001 A (0-0.5 A) | |
| Photometric noise | 0.0004 A (500 nm, 30 min warm-up) | |
| Baseline flatness | 0.001 A (200-850 nm) | |
| Baseline stability | 0.0008 A/h (500 nm, 0 Abs, 2hrs warm-up) | |
| Stray light | ≤0.01 %T (220 nm NaI, 340 nm NaNO2) | |
| Standard functionality | No stand alone function | |
| Cell holder | Fixed position sample and reference | |
| Detector | Photo multiplier tube | |
| Light source | Tungsten Halogen and Deuterium arc lamps | |
| Display | No display | |
| Printer | Not available | |
| PC interface | RS232, USB | |
| Software support | UV Win | |
| Power supply | Switch mode 120-230 VAC 50-60 Hz | |
| Weight | 95 lb | |
| Dimension | 21.5 x 23 x 11 in | |
| MODEL | PART NO | DESCRIPTION |
| T8DCS | 1950 | Double beam Spectrometer with fixed cell holder, wavelength range 190-900nm with a user defined bandpass from 0.1-5.0nm in increments of 0.1nm. PC controlled by USB or RS232 cable. |
RE601C-O- Rotary EvaporatorRE601C-O - Yamato
701222030- FreeZone 12 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
88870116, Digital and Touchscreen Dry Bath Accessories Thermo Scientific- 15mL Flat-Bottom Tube Block
S-1205 -Productivity Series Spectrophotometer- Unico
RE601B-W - Rotary EvaporatorRE601B-W - Yamato
3970302- 3' Purifier Filtered PCR Enclosure with UV Light and Protection Panel- Labconco
RE301C-WV - Rotary evaporator, Glass "C", Water Bath, VR300 - Yamato
SE915 Large Format PAGE Multiple Gel Caster for Use with SE9102 Cassettes Hoefer
4318 Polypropylene 0.5ml Graduated Flat Top Microcentrifuge Tube,Blue Bio Plas
EAB 224i -Equinox Semi-Micro and Analytical Balances- Adam Equipment
F144066-PIPETMAN G P5000G, 500-5000 µL-Gilson
F144068-PIPETMAN G Multichannel P8x10G, 1-10µL-Gilson
A-106193, Didactic Skull On Cervical Vertebrae With Nerves And Arteries Axis Scientific
A-105940, 22 Part Osteopathic Natural Bone Human Skull Axis Scientific
A-105182, 3-Part Heart (3x Life-Size) Axis Scientific
06-209-15 - 15 Ml Omni Prep Tube Holder- Omni International
A-105172 Human Skeleton With Flexible Spine, Muscle Insertions, And Ligaments Axis Scientific
49000162 Occasional Metrology Delivery / Airwel Alliance Bio Expertise
19-353-0150 - Omni Bead Ruptor 12 Microtube Adapter, 4-Pack- Omni International
A-105176 Disarticulated Half Child Skeleton Axis Scientific
C8724E -PowerSpin™ DX Centrifuge- Unico
911015119999 D2012 Plus High Speed Personal Micro-Centrifuge Scilogex 


