T8DS is a high performance double beam scanning spectrophotometer with a variable spectral bandwidth.
The Czerny-Turner Monochromator with a holographic grating keeps stray light at a minimum and offers excellent optical resolution.
The use of a photomultiplier tube as detector delivers exceptional sensitivity.
The true double-beam optical system coupled with an efficient and well proven electronic control system ensures high stability and low background noise.
Key Features
- Czerny-Turner Monochromator with high resolution holographic grating
- High performance variable (0.1, 0.2, 0.5, 1.0, 2.0, 5.0nm) spectral bandwidth
- High resolution, excellent performance, long term stability
- Additional accessories for multi-application, support the ultra-volume cuvettes
| Specifications | ||
| Optical system | Double beam | |
| Scan speed | Selectable | |
| Wavelength range | 190-1100 nm | |
| Wavelength accuracy | ±0.3 nm | |
| Wavelength reproducibility | ≤0.1 nm | |
| Spectral bandwidth |
0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm |
|
| Photometric mode | Transmittance, Absorbance, Energy Concentration, all using UVWin software | |
| Photometric range | -4.0-4.0 Abs | |
| Photometric accuracy | 0.002 A (0-0.5 A), 0.004 A (0.5-1 A), 0.3 %T (0-100 %T) | |
| Photometric reproducibility | 0.001 A (0-0.5 A) | |
| Photometric noise | 0.0004 A (500 nm, 30min warm-up) | |
| Baseline flatness | 0.001 A (200-850 nm) | |
| Baseline stability | 0.0008 A/h (500 nm, 0 Abs, 2hrs warm-up) | |
| Stray light | ≤0.12 %T (220 nm NaI, 340 nm NaNO2) | |
| Standard functionality | Photometric, Quantitative, Spectrum and DNA measurements | |
| Cell holder | Fixed position sample and reference | |
| Detector | Photo multiplier tube | |
| Light source | Tungsten Halogen and Deuterium arc lamps | |
| Display | No display | |
| Printer | Not available | |
| PC interface | RS232, USB | |
| Software support | UV Win | |
| Power supply | Switch mode 120-230 VAC 50-60 Hz | |
| Weight | 95 lb | |
| Dimension | 21.5 x 23 x 11 in | |
| MODEL | PART NO | DESCRIPTION |
| T8DS | 1901 | True double beam UV-Vis Spectrometer with fixed cell holder, 190-900nm, variable 0.1,0.2,0.5,1.2,5nm bandwidth, PC controlled |
A-104277, 8-Part Deluxe Human Brain with Arteries Axis Scientific
A-105939, 22 Part Osteopathic Didactic Human Skull Axis Scientific
F144059M-PIPETMAN G P1000G, 100-1000 µL, Metal Ejector-Gilson
F144057M-PIPETMAN G P100G, 10-100 µL, Metal Ejector-Gilson
F81042-PIPETMAN M P100M BT Connected-Gilson
S58L Premier Academic Kinesiology Skeleton, Painted And Labeled, Sacral Mount On Mobile Stand- Denoyer Geppert
F81040-PIPETMAN M P10M BT Connected-Gilson
701811010-FreeZone 18 Liter -50C Console Freeze Dryer- Labconco
4305 Polypropylene 1.5ml Graduated Flat Top Microcentrifuge Tube, Amber Bio Plas
0091 Polypropylene Reversible 1.5ml And 2.0ml Microcentrifuge Tube Rack, 96 Places (Pack Of 5) Bio Plas
4306 Polypropylene 1.5ml Graduated Flat Top Microcentrifuge Tube, Orange Bio Plas
FA10005M-PIPETMAN L P200L, 20-200 µL, Metal Ejector-Gilson
R1056- Quick-RNA Midiprep Kit 25 preps- Zymo Research
3970223- 2' Purifier Vertical Clean Bench with Airflow Monitor- Labconco
F144074-PIPETMAN G Multichannel P8x300G, 30-300µL-Gilson 



