QIAGEN Plasmid Kits provide gravity-flow, anion-exchange tips for purification of transfection-grade plasmid DNA. Lysate clearing and isopropanol precipitation are achieved by centrifugation.
The QIAGEN Plasmid Mega Kit (cat. no. 12181) and the QIAGEN Plasmid Giga Kit (cat. no. 12191) can be used with the QIAfilter Mega-Giga Cartridges (cat. no. 19781) as an optional protocol step for rapid clearing of bacterial lysates by filtration instead of centrifugation. See more information regarding principle below.
Performance
The QIAGEN Plasmid Kits uses gravity-flow QIAGEN anion-exchange tips for efficient purification of plasmid DNA. Up to
10 mg (giga), 2.5 mg (mega), 500 µg (maxi), 100 µg (midi), and 20 µg (mini) high-copy plasmid DNA is purified from culture (culture volumes depend on plasmid copy number, size of insert, host strain, and culture medium). Plasmid DNA purified with QIAGEN Plasmid Kits is highly suitable for use in applications such as transfection (see figure ” Transfection efficiency versus plasmid purification method”), cloning, and in vitro transcription.
Principle
The unique anion-exchange resin in QIAGEN-tips is developed exclusively for the purification of nucleic acids. Its exceptional separation properties result in DNA purity equivalent or superior to that obtained by two successive rounds of CsCl gradient centrifugation. Prepacked QIAGEN-tips operate by gravity flow and never run dry, minimizing the hands-on time required for plasmid preparation. The entire QIAGEN plasmid purification system avoids the use of toxic substances such as phenol, chloroform, ethidium bromide, and CsCl, minimizing hazard both to the user and the environment.
As an optional protocol step for rapid clearing of bacterial lysates by filtration instead of centrifugation, you can use the QIAfilter Mega-Giga Cartridges (cat. no. 19781), which operate with house vacuum to efficiently clear even large volumes of bacterial lysate with minimal effort. The protocol is available in the handbook.
| Features | Plasmid Giga Kit | Plasmid Mega Kit | Plasmid Maxi Kit | Plasmid Midi Kit | Plasmid Mini Kit |
| Applications | Transfection, cloning, sequencing, capillary sequencing, etc. | Transfection, cloning, sequencing, capillary sequencing, etc. | Transfection, cloning, sequencing, capillary sequencing, etc. | Transfection, cloning, sequencing, capillary sequencing, etc. | Transfection, cloning, sequencing, capillary sequencing, etc. |
| Culture volume/starting material | 2.5–5 liters culture volume | 500 ml – 2.5 liters culture volume | 100–500 ml culture volume | 25–100 ml culture volume | 3–10 ml culture volume |
| Elution volume | Variable | Variable | Variable | Variable | Variable |
| Plasmid type | High-copy, low-copy, cosmid DNA | High-copy, low-copy, cosmid DNA | High-copy, low-copy, cosmid DNA | High-copy, low-copy, cosmid DNA | High-copy, low-copy, cosmid DNA |
| Processing | Manual (gravity flow) | Manual (gravity flow) | Manual (gravity flow) | Manual (gravity flow) | Manual (gravity flow) |
| Sample per run | 1 sample per run | 1 sample per run | 1 sample per run | 1 sample per run | 1 sample per run |
| Technology | Anion-exchange technology | Anion-exchange technology | Anion-exchange technology | Anion-exchange technology | Anion-exchange technology |
| Time per run | 320 min | 220 min | 160 min | 150 min | 80 min |
| Yield | <10 mg | <2.5 mg | <500 µg | up to 100 µg | <20 µg |
Procedure
With QIAGEN Plasmid Kits, bacterial lysates are cleared by centrifugation. The cleared lysate is then loaded onto the anion-exchange tip where plasmid DNA selectively binds under appropriate low-salt and pH conditions. RNA, proteins, metabolites, and other low-molecular-weight impurities are removed by a medium-salt wash, and pure plasmid DNA is eluted in high-salt buffer (see flowchart ” QIAGEN Plasmid Kit procedures”). The DNA is concentrated and desalted by isopropanol precipitation and collected by centrifugation.
Applications
Plasmid DNA purified with QIAGEN Plasmid Kits is highly suitable for use in applications, such as:
- Transfection
- Cloning
- PCR
- In vitro transcription
3970201- ' Purifier Vertical Clean Bench with UV Light and Protection Panel- Labconco
YS3060, Grating Spectrophotometer with UV SCI/SCE Bluetooth 3nh
710611010-FreeZone 6 Liter -84C Console Freeze Dryer- Labconco
PTM 500 Drum and Wheelchair Platforms Adam Equipment
711211210-FreeZone 12 Liter -84C Console Freeze Dryer- Labconco
YS6010, Benchtop grating spectrophotometer 3nh
28115-QIAquick Spin Columns (100)- Qiagen
OR-T-156 - 5/32" Diameter Stepped Micro-Tip For Ultrasonic Homogenizer - Omni International
VE-M5 BIOLOGICAL MONOCULAR MICROSCOPE -VELAB
12010-2E -S-EVAP-KD 10 position, bath 1600W for 250mL Kuderna Danish flasks - Organomation
F144056M-PIPETMAN G P20G, 2-20 µL, Metal Ejector-Gilson
81-12110-00, Omega Lum™ C Imaging System Gel Company
700611230- FreeZone 6 Liter -50C Console Freeze Dryer- Labconco
WA731 - Water Purifier (Ion-exchange + Distillation, Large Capacity)WA731- Yamat
D4213 - ZymoPURE - Express Plasmid Midiprep Kit 25 preps- Zymo Research
S54 Premier Academic Series Skeleton With Natural Tone 18 Pc Take-Apart Skull And Sacral Mount Mobile Stand- Denoyer Geppert
R1101-1-10 - Feces Catcher 10 pack- Zymo Research
LBL 24001e - Luna LBL Heavy Duty Precision Balance-Adam Equipment
BSH100-05 Block, 24 x 0.5ml Benchmark Scientific
MAA544HU22-Anti-IgG Mouse Monoclonal Antibody [clone: C2]- Cloude Clone
718-8804- SAM4 Auscultation Manikin -Cardionics
701222010- FreeZone 12 Liter -50C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
75144-RNeasy Midi Kit (50)- Qiagen
800EG 1 Liter Blenders Waring
701212010- FreeZone 12 Liter -50C Console Freeze Dryer- Labconco
EZ-110 Mouse Nosecone - E-Z Systems
4307 Polypropylene 1.5ml Graduated Flat Top Microcentrifuge Tube, Lavender Bio Plas
F144067-PIPETMAN G P10mLG, 1-10 mL-Gilson
MAA541MU21-Anti-BNP Mouse Monoclonal Antibody [clone: C10]-Cloud-Clone
BCLO2026 Clu Usb Bluetooth Alliance Bio Expertise
LAB 214i -Luna Analytical Balances- Adam Equipment
CRQRC-SCC - Quric™ SCC - Curiosis
E1101-COMB1 Double Sided Combs, 22* 12 teeth, for E1101-CS1 Casting Set, pk. 2 Accuris
MAA537HU21-Anti-NSE Mouse Monoclonal Antibody [clone: C12]-Cloud-Clone
PAA402RA02-Anti-MMP12 Rabbit Polyclonal Antibody- Cloude Clone
88870112, Digital and Touchscreen Dry Bath Accessories Thermo Scientific-Mixed Block, 6mm and 10mm dia
F144071-PIPETMAN G Multichannel P12x20G, 2-20µL-Gilson
EZ-RB1000 - Veterinary Anesthesia Machine with TEC 3 Vaporizer - E-Z Systems
F167800-PIPETMAN G Microvolume Starter Kit, P2G, P10G, P100G-Gilson
A-105182, 3-Part Heart (3x Life-Size) Axis Scientific
701211230- FreeZone 12 Liter -50C Console Freeze Dryer- Labconco
0718-00 Multi-Torso Male / Female / Sexless And 3rd Trimester Insert- Denoyer Geppert
STB 3202i -Solis Precision Balances- Adam Equipment
M152- Intramuscular Injection Model of Buttocks- Sakamoto
BCLO3034 IQ/OQ protocol For GAS SYSTEM (English version) Alliance Bio Expertise
D5101 - Methylated-DNA IP Kit 10 Rxns.- Zymo Research
F167300-PIPETMAN Classic Starter Kit, P20, P200, P1000-Gilson
QIAamp DNA Blood Mini Kit (250) - 51106 - Qiagen 


