Large capacity, high performance, fully automatic sterilization from start to finish with high pressure steam sterilization and drying steps
Operation and functions
- Interactive keypad input (touch panel) allows committing sterilization settings (time & temperature) to memory
- 7″ interactive touch screen
- Suitable for protein modification at the maximum operating temperature of 135°C
- Easy settings and operation modes for a multitude of sterilization process
- Increased safety and function list including forced cooling and memory functions
- Equipped with multiple safety locking mechanism for the lid
- Comes with large capacity (11L) heat resistant stainless steel container
- Alarm buzzer sounds when high or low pressure error occurs
| Model | SM520 | SM530 | SM820 | SM830 | ||
| System | Automatic high pressure steam sterilization | |||||
| Operating Temperature | Sterilize | 105 to 135°C | ||||
| Liquefy | 60 to 110°C | |||||
| Retain | 45 to 60°C | |||||
| Preheat | 45 to 80°C | |||||
| Dry | 135 to 150°C | |||||
| Operating Ambient Temp. | 5 to 35°C | |||||
| Maximum Pressure Capacity | 0.255MPa | |||||
| Heating | Sterilize Pipe | 1000W ×2 | ||||
| Drying Pipe | 110V/295W×2, 110V/455W×2 | 110V/295W×2, 110V/455W×2 | 110V/275W ×2, 110V/625W ×2 | 110V/275W ×2, 110V/625W ×2 | ||
| Temp. Controller | PlD controlled by microprocessor | |||||
| Temp. Setting / Display | Touch panel | |||||
| Timer / Timer Resolution | Range: 0 or 1min to 99h59min / 1 min. | |||||
| Safety Device | Sterilize sensor error, sterilize SSR short circuit, dry sensor error, dry SSR short circuit, sterilize heater disconnection, dry heater disconnection, water level detection (liquid expansion method), independent chamber overheat protection, cover unlock error, chamber over pressure protection, under pressure protection, warning about setting error in cooling water container, memory error, pressure switch (0.25MPa), pressure safety valve (0.255MPa) | |||||
| Internal Dimensions | Ø370 x D470 mm | Ø370 x D470 mm | Ø370 x D750 mm | Ø370 x D750 mm | ||
| External Dimensions WxDxH | 520 x 660 x 881 mm | 520 x 660 x 881 mm | 520 x 660 x 116 mm | 520 x 660 x 1161 mm | ||
| Internal Capacity | 50L | 50L | 80L | 80L | ||
| Power Source (50/60Hz) | Voltage | AC100-120V (no plug, round terminal) | AC200-240V (no plug, round terminal) | AC100-120V (no plug, round terminal) | AC200-240V (no plug, round terminal) | |
| Sterilize current | 25-21A | 12.5-10.5A | 25-21A | 12.5-10.5A | ||
| Dry current | 13.5A | 8.0A | 15.0A | 9.0A | ||
| Weight | ~113kg | ~113kg | ~137kg | ~137kg | ||
F123789-PIPETMAN Fixed F400, 400 µL-Gilson
LTB 2602e -Luna Precision Balances- Adam Equipment
BSW108 Block, 20 x 10mm (or 20 x 2.0ml) Benchmark Scientific
DKN-912C - Forced Convection Oven Programmable 535L 220V- Yamato
NBL 22001e -Nimbus® Precision Large Pan Balances- Adam Equipment
GR148-1 - Tris-Glycine (TG) Buffer,10X Solution (Ultrapure)- Hoefer
PAG436HU01-Anti-DSC2 Rabbit Polyclonal Antibody- Cloude Clone
710621070-FreeZone 6 Liter -84C Console Freeze Dryer with Stoppering Tray Dryer- Labconco
PAA643HU01 - Anti-GSTm4 Rabbit Polyclonal Antibody -Cloud-Clone
SEH821MU-Mouse IL18BP ELISA Kit-Clone
MAA207HU22-Anti-ALT Mouse Monoclonal Antibody [clone: C1]-Cloud-Clone
HGB55E 2 Liter with Stainless Steel Container Waring 