Make the chore of introducing nucleic acids into cells easier. BTX Harvard ECM 830 Series Electroporator System can be used in applications covering embryo manipulation techniques, in-vivo gene therapy electroporation, in vitro embryo gene delivery, plant protoplast transformation, in-ovo gene delivery, siRNA transfections, and zebrafish electroporation.
- ECM 830 Square Wave Pulse generator designed for in vitro and in vivo applications including gene, drug and protein delivery include; mammalian cells, in vivo, ex vivo tissue, zebra fish tissue and embryos, nuclear transfer, embryo manipulation, plant protoplast and basic bacteria and yeast transformations
- ECM 830 can be used in combination with a wide array of BTX specialty electrodes and accessories to enhance molecular and drug delivery experiments
- System components include: ECM 830 Generator, 630B Safety Stand, Cuvettes 1 mm, 2 mm, 4 mm pkg. of 30 (10 each) and Cuvette Rack 660
| SPECIFICATIONS FOR THE ECM 830 | |
| Certifications | CE Mark |
| Pulse Waveform | Square Wave |
| DC Voltage Range LV Mode | 5 to 500 V / 1 V resolution |
| DC Voltage Range HV Mode | 505 to 3000 V / 5 V resolution |
| DC Pulse Length Range LV Mode 1 | 10 µsec to 999 µsec / 1 µsec resolution |
| DC Pulse Length Range LV Mode 2 | 1 msec to 999msec / 1 msec resolution |
| DC Pulse Length Range LV Mode 3 | 1 sec to 10 sec / 0.1 sec resolution |
| DC Pulse Length Range HV Mode | 10 to 600 µsec / 1 µsec resolution |
| Multi-Pulsing | 1 to 99 |
| Pulse Interval | 100 msec to 10 sec |
| Programmability | Storage for 2 parameters (V, t, n, interval) |
| Arc Control | Arc Quenching™ |
| Safety | Generator is short circuit proof |
| Capacitance LV Mode | 4000 µF |
| Capacitance HV Mode | 111 µF |
| Internal Resistance LV Mode | 56 ? |
| Internal Resistance HV Mode | 56 ? |
| Opererational Status | Internal self test upon start-up |
| Interface | Digital User Interface |
| Power | 100 to 240 VAC, 50/60 Hz |
| Charge Time | 5 sec maximum (without delay) |
| Display | 4 line x 20 character LCD |
| Controls | Single rotary knob with push button toggle to set parameters. On/Off Power and Start switches |
| Electroporation Chamber | Safety Stand or Plate Handler |
| Monitoring | Monitoring and display of V, t, n, interval |
| MOS Multi-Well Compatible | Yes |
| Remote Operation | Foot Switch Available |
| Height Metric | 14 cm |
| Height English | 5.5 in |
| Width Metric | 31.8 cm |
| Width English | 12.5 in |
| Depth Metric | 31.1 cm |
| Depth English | 12.25 in |
| Weight Metric | 6.8 kg |
| Weight English | 15 lbs |
GR142-100 -N,N’ - Methylene-bis-Acrylamide 100gr- Hoefer
EZ-115 Rabbit/ Guinea Pig Nosecone - E-Z Systems
FP-303 - High Performance Muffle Furnace 7.5L 115V- Yamato
RE301C-W - Rotary evaporator, Glass "C", Water BathRE301C-W - Yamato
MAA095HU21-Anti-MIP3a Mouse Monoclonal Antibody [clone: A4]-Cloud-Clone
PMB 202-115V - PMB Moisture Analyzer-Adam Equipment
PMB 202 -PMB Moisture Analyzer- Adam Equipment
PAA037HU01 -Anti-FN Rabbit Polyclonal Antibody -Cloud-Clone
SF2600- Stat Fax®2600- Awareness Technology
SEH821MU-Mouse IL18BP ELISA Kit-Clone
F123790-PIPETMAN Fixed F500, 500 µL-Gilson
BCLO2025 Protective Cover For Stainless Steel Grid Alliance Bio Expertise
F144071-PIPETMAN G Multichannel P12x20G, 2-20µL-Gilson
F81053-PIPETMAN M P12X100M BT Connected-Gilson 